PSC 100-150web

PSC-series DC/DC 100-150W 1 to 3 Outputs

Input / Output

  • Wide input voltage ranges.
  • Single outputs from 5 to 48V.
  • Two or three output 5V to 24V.
  • Reverse input voltage protection.

Operation

  • High efficiency.
  • Operating temperature range.
  • -25 to +70°C with no derating.
  • Fully encapsulated, meets IP30 as standard.
  • Convection cooled.
  • Inhibit /Power Down input.
  • Low voltage alarm, open collector.

Features

  • Conformally coating, tropic.
  • Under voltage logic alarm.
  • Accesible from front panel:
    • Output voltage adjustment.
    • Output voltage measurement.
    • Output OK status green LED.

EMC

  • EN61000-6-3 Emission.
  • EN61000-6-2 Immunity.
  • EN/IEC61000-4-4, 4kV.
  • EN/IEC61000-4-5 level 2 & 3.

Output

Input

Voltage

Current

Power

10 - 30V

20 - 60V

40 - 100V

50 - 150V

90 - 270V.

250 - 500V

Case

5V

20.0A1

100W

PSC100A5

PSC100B5

PSC100CT5

PSC100C5

PSC100D5

--

10TE

5V

30.0A1

150W

PSC150A5

PSC150B5

PSC150CT5

PSC150C5

PSC150D5

--

12TE

12V

8.3A

100W

PSC100A12

PSC100B12

PSC100CT12

PSC100C12

PSC100D12

--

10TE

12V

12.5A

150W

PSC150A12

PSC150B12

PSC150CT12

PSC150C12

PSC150D12

--

12TE

13.6V

7.4A

100W

PSC100A13.2

PSC100B13.2

PSC100CT13.2

PSC100C13.2

PSC100D13.2

--

10TE

13.6V

11.0A

150W

PSC150A13.2

PSC150B13.2

PSC150CT13.2

PSC150C13.2

PSC150D13.2

--

12TE

15V

6.7A

100W

PSC100A15

PSC100B15

PSC100CT15

PSC100C15

PSC100D15

--

10TE

15V

10.0A

150W

PSC150A15

PSC150B15

PSC150CT15

PSC150C15

PSC150D15

--

12TE

24V

4.2A

100W

PSC100A24

PSC100B24

PSC100CT24

PSC100C24

PSC100D24

PSC100E24

10TE

24V

6.3A

150W

PSC150A24

PSC150B24

PSC150CT24

PSC150C24

PSC150D24

PSC150E24

12TE

48V

2.1A

100W

PSC100A48

PSC100B48

PSC100CT48

PSC100C48

PSC100D48

PSC100E48

10TE

48V

3.1A

150W

PSC150A48

PSC150B48

PSC150CT48

PSC150C48

PSC150D48

PSC150E48

12TE

How to read our product code:
Example PSC100C24
PSC100
= Family code
C = input voltage code B
24 = Output voltage 24V

Input Voltage ranges

Nominal inputs

 Input range

Code

12, 24 Vd.c.

10 to 30V

A

24, 28, 36, 48 Vd.c.

20 to 60V

B

48, 60, 72 Vd.c.

40 to 100 V

CT

72, 96, 110, 127 Vd.c.

50 to 150 V

C

110, 127, 220, 250Vd.c.

90 to 270 V

D

350, 440Vd.c.

250 to 500 V

E

Single output ratings

Voltage

Output Current

Power

5V

20 - 30A

100 - 150W

12V

8 - 12.5A

100 - 150W

15V

7 - 10A

100 - 150W

24V

4 - 6A

100 - 150W

36V

3 - 4A

100 - 150W

48V

2 - 3A

100 - 150W

Other input ranges on demand.

T-input for Mobile application ranges

Uin 0.1s- S2

Continous range

Code

14.4 - 33.6Vd.c.

16.8 - 30Vd.c.

24T

21.6 - 50.4Vd.c.

25.2 - 45Vd.c.

36T

28.8 - 67.2Vd.c.

33.6 - 60Vd.c.

48T

43.2 - 100.8Vd.c.

50.4 - 90Vd.c.

72T

66 - 154Vd.c.

77 - 137.5Vd.c.

110T

The total output power can be derated on a T-range compared to the above output rating table page 2. Input voltage range according to train standard EN50155:2001 and IEC60571:1998.

2-3 outputs ratings

Master Output

Auxiliary Output

Total Power

5V   15 - 25A

±12V 1.2A

100 - 150W

5V   15 - 25A

12V 1.2A

100 - 150W

5V   15 - 25A

±15V 1.2A

100 - 150W

5V   15 - 25A

15V 1.2A

100 - 150W

12V  7.3 - 11A

5V 2.5A2

100 - 150W

12V  7 - 11A

12V 1.2A

100 - 150W

15V  5 - 8A

15V 1.2A

100 - 150W

24V  3 - 4.3A

24V 1.2A

100 - 150W

2 Common zero on the output.

100 - 150 W Single output

Features

  • Single outputs from 5 to 48 V.
  • Operating temperature range
    -25 to +70°C.
    •Fully Encapsulated meets IP30.
  • Convection cooled.
  • Low voltage alarm, open collector.
  • Inhibit / Power Down input.
  • Conformal coating, Tropic.
  • Compatible AC inputs models.
    Please ask for PSC-AC Datasheet.
    100 - 150 W Single output

    1 Operating temperature range, see 2 outputs. Other input and outputs combination on demand.

    100 to 150W High Power 2&3 Outputs

    Features

    • Master Outputs from 5 to 48 V
    • One auxiliary voltage 5 to 30V
    • Second auxiliary voltage 5 to 15V
    • Operating temperature range
      -25 to +70°C. +70°C with derating.
    • Fully Encapsulated meets IP30.
    • Convection cooled.
    • Low voltage alarm, open collector.
    • Inhibit / Power Down input.
    • Conformal coating, Tropic.
    • Compatible AC input models.
      Please ask for PSC-AC datasheet.
      Two outputs all input codes

      Master Output

      Auxiliary Output

      Total Power

      Input

      10 - 30V

      20 - 60V

      40 - 100V

      50 - 150V

      90 - 270V

      Case

      5V   17A

      12V  1.2A

      100W

      PSC100A5S12

      PSC100B5S12

      PSC100CT5S12

      PSC100C5S12

      PSC100D5S12

      10TE

      5V   25A

      12V  1.2A

      150W

      PSC150A5S12

      PSC150B5S12

      PSC150CT5S12

      PSC150C5S12

      PSC150D5S12

      12TE

      5V   17A

      15V  1.2A

      100W

      PSC100A5S15

      PSC100B5S15

      PSC100CT5S15

      PSC100C5S15

      PSC100D5S15

      10TE

      5V   25A

      15V  1.2A

      150W

      PSC150A5S15

      PSC150B5S15

      PSC150CT5S15

      PSC150C5S15

      PSC150D5S15

      12TE

      12V  7.3A

      5V   2.5A2

      100W

      PSC100A12S5

      PSC100B12S5

      PSC100CT12S5

      PSC100C12S5

      PSC100D12S5

      10TE

      12V  11A

      5V   2.5A2

      150W

      PSC150A12S5

      PSC150B12S5

      PSC150CT12S5

      PSC150C12S5

      PSC150D12S5

      12TE

      12V  7A

      12V  1.2A

      100W

      PSC100A12S12

      PSC100B12S12

      PSC100CT12S12

      PSC100C12S12

      PSC100D12S12

      10TE

      12V  11A

      12V  1.2A

      150W

      PSC150A12S12

      PSC150B12S12

      PSC150CT12S12

      PSC150C12S12

      PSC150D12S12

      12TE

      15V  5.5A

      12V  1.2A

      100W

      PSC100A15S15

      PSC100B15S15

      PSC100CT15S15

      PSC100C15S15

      PSC100D15S15

      10TE

      15V  9A

      15V  1.2A

      150W

      PSC150A15S15

      PSC150B15S15

      PSC150CT15S15

      PSC150C15S15

      PSC150D15S15

      12TE

      24V  3A

      24V  1.2A

      100W

      PSC100A24S24

      PSC100B24S24

      PSC100CT24S24

      PSC100C24S24

      PSC100D24S24

      10TE

      24V    5A

      24V  1.2A

      150W

      PSC150A24S24

      PSC150B24S24

      PSC150CT24S24

      PSC150C24S24

      PSC150D24S24

      12TE

      2 Common zero on the output.
      Operating temperature range  -25 to +55°C. For 70°C derate PSC100 to 75 W &PSC150 to 110W. The secondary output voltage are only factory adjustable.
      Higher continous auxilliary current up to 2.5A if the input voltage range is derated.

      How to read our product code:
      Example PSC150B12S5
      PSC150
      = Family code & output power
      B = input voltage code
      S5 = Master output
      S5 = Stabilized slave output

      Three outputs A, B Input codes
      Three outputs CT, C, D Input codes

      Master Output

      Auxiliary Output

      Total Power

      Input

      10 - 30V

      20 - 60V

      Case

      5V 11A

      ±12V 1.2A

      100W

      PSC100A5S12-12

      PSC100B5S12-12

      10TE

      5V 20A

      ±12V 1.2A

      150W

      PSC150A5S12-12

      PSC150B5S12-12

      12TE

      5V 10A

      ±15V 1.2A

      100W

      PSC100A5S15-15

      PSC100B5S15-15

      10TE

      5V 20A

      ±15V 1.2A

      150W

      PSC150A5S15-15

      PSC150B5S15-15

      12TE

      Master Output

      Auxiliary Output

      Total Power

      Input

      40 - 100V

      50 - 150V

      90 - 270V

      Case

      5V 11A

      ±12V 2A

      100W

      PSC100CT5S12-12

      PSC100C5S12-12

      PSC100D5S12-12

      10TE

      5V 20A

      ±12V 2A

      144W

      PSC150CT5S12-12

      PSC150C5S12-12

      PSC150D5S12-12

      12TE

      5V 10A

      ±15V 2A

      100W

      PSC100CT5S15-15

      PSC100C5S15-15

      PSC100D5S15-15

      10TE

      5V 20A

      ±15V 2A

      150W

      PSC150CT5S15-15

      PSC150C5S15-15

      PSC150D5S15-15

      12TE

      See comments below

      Operating temperature range  -25 to +55°C. For 70°C derate PSC100 to 75 W & PSC150 to 110W. The two secondary output use common zero for ±12 or ±15 application or to supply -24V or 30V. The secondary output voltage are only factory adjustable. Higher continous auxilliary current up to 2.5A if the input voltage range is derated.

      dc-about-drop02

      DC/DC Converters PSC100 / PSC150

      Updated: February 21, 2006

      Polyamp AB
      Box 229
      SE-597 25 Åtvidaberg, Sweden
      Tel: +46 120 854 00 Fax: +46 120 854 05


      All Rights Reserved © Polyamp AB
      e-mail: Polyamp
      Webmaster: Webmaster
      Site Made by Teknorama Soft

      RoHS