Input / Output
Operation
Features
EMC
How to read our product code:
Example PU500 24/48
PU500 = Family code
24 = input voltage code 24
48 = Output voltage 48V
Output | Input | |||||
Voltage | Current | Power | 18 - 32V | 38 - 60V | 88 - 150V | 175 - 300V |
24V | 16.7A | 400W | PU500 24/24 |
|
|
|
24V | 20.9A | 500W |
| PU500 48/24 | PU500 110/24 | PU500 220/24 |
28V | 14.3A | 400W | PU500 24/28 |
|
|
|
28V | 17.9A | 500W |
| PU500 48/28 | PU500 110/28 | PU500 220/28 |
36V | 11.2A | 400W | PU500 24/36 |
|
|
|
36V | 13.9A | 500W |
| PU500 48/36 | PU500 110/36 | PU500 220/36 |
48V | 8.4A | 400W | PU500 24/48 |
|
|
|
48V | 10.5A | 500W |
| PU500 48/48 | PU500 110/48 | PU500 220/48 |
60V | 6.7A | 400W | PU500 24/60 |
|
|
|
60V | 8.4A | 500W |
| PU500 48/60 | PU500 110/60 | PU500 220/60 |
Nominal inputs | Input range | Code |
24 Vd.c. | 18 to 32V | 24 |
48 Vd.c. | 38 to 60V | 48 |
110, 127 Vd.c. | 88 to 150V | 110 |
220, 250 Vd.c. | 175 to 300V | 220 |
Input voltages meeting train standard
EN50155/IEC60571, can be made on demand.
Voltage | Output Current | Power |
24V | 16.7 - 20.9A | 400 - 500W |
28V | 14.3 - 17.9A | 400 - 500W |
36V | 11.2 - 13.9A | 400 - 500W |
48V | 8.4 - 10.5A | 400 - 500W |
60V | 6.7 - 8.4A | 400 - 500W |


DC/DC Converters PU500
Updated: February 21, 2006
Polyamp AB
Box 229
SE-597 25 Åtvidaberg, Sweden
Tel: +46 120 854 00 Fax: +46 120 854 05
All Rights Reserved © Polyamp AB
e-mail: Polyamp
Webmaster: Webmaster
Site Made by Teknorama Soft