32 to 50W DC/DC converter 1 & 2 outputs low noise high MTBF |
|
|

PM50-series
Polyamp PM50 series with 2 flexible outputs that covers 12V - 32V with one model and 60V & 120V with another. The output has very low ripple and power varies 32-50W. Very wide input voltage ranges from 10V to 270Vd.c. and very high practical MTBF over 3 Million hours. CE marked as fee standing unit. Intended to be mounted on wall, DIN rail or chassis mount. Operating temperature range -25°C +55°C.
Output voltage rating and type code
|
Output
|
Input voltage range
|
Voltage
|
Current
|
Power
|
10 - 30V
|
20 - 60V
|
50 - 150V
|
90 - 270V
|
Output connected
|
|
12V
|
2.67A
|
32W
|
PM50A15-15
|
|
|
|
Parallel
|
|
12V
|
3.34A
|
40W
|
|
PM50B15-15
|
PM50C15-15
|
PM50D15-15
|
Parallel
|
|
15V
|
2.67A
|
40W
|
PM50A15-15
|
|
|
|
Parallel
|
|
15V
|
3.34A
|
50W
|
|
PM50B15-15
|
PM50C15-15
|
PM50D15-15
|
Parallel
|
|
18V
|
2.60A
|
47W
|
PM50A18-18
|
|
|
|
Parallel
|
|
18V
|
3.20A
|
57W
|
|
PM50B18-18
|
|
|
Parallel
|
|
18V
|
2.78A
|
50W
|
|
|
PM50C18-18
|
|
Parallel
|
|
24V
|
1.34A
|
32W
|
PM50A15-15
|
|
|
|
Series
|
|
24V
|
1.67A
|
40W
|
|
PM50B15-15
|
PM50C15-15
|
PM50D15-15
|
Series
|
|
28V
|
1.34A
|
37W
|
PM50A15-15
|
|
|
|
Series
|
|
28V
|
1.67A
|
47W
|
|
PM50B15-15
|
PM50C15-15
|
PM50D15-15
|
Series
|
|
36V
|
1.30A
|
47W
|
PM50A18-18
|
|
|
|
Series
|
|
36V
|
1.60A
|
57W
|
|
PM50B18-18
|
|
|
Series
|
|
36V
|
1.39A
|
50W
|
|
|
PM50C18-18
|
|
Series
|
|
60V
|
0.67A
|
40W
|
PM50A60-60
|
|
|
|
Parallel
|
|
60V
|
0.84A
|
50W
|
|
PM50B60-60
|
PM50C60-60
|
PM50D60-60
|
Parallel
|
|
110V
|
0.34A
|
37W
|
PM50A60-60
|
|
|
|
Series
|
|
110V
|
0.42A
|
46W
|
|
PM50B60-60
|
PM50C60-60
|
PM50D60-60
|
Series
|
Two outputs ratings
|
Output
|
Input voltage range
|
Voltage
|
Current
|
Voltage
|
Current
|
Power
|
10 - 30V
|
20 - 60V
|
50 - 150V
|
90 - 270V
|
|
12V
|
1.34A
|
12V
|
1.34A
|
32W
|
PM50A15-15
|
|
|
|
|
12V
|
1.67A
|
12V
|
1.67A
|
40W
|
|
PM50B15-15
|
PM50C15-15
|
PM50C15-15
|
|
15V
|
1.34A
|
15V
|
1.34A
|
40W
|
PM50A15-15
|
|
|
|
|
15V
|
1.67A
|
15V
|
1.67A
|
50W
|
|
PM50B15-15
|
PM50C15-15
|
PM50D15-15
|
|
18V
|
1.60A
|
18V
|
1.60A
|
57W
|
|
PM50B18-18
|
|
|
|
18V
|
1.39A
|
18V
|
1.39A
|
50W
|
|
|
PM50C18-18
|
|
|
60V
|
0.34A
|
60V
|
0.34A
|
40W
|
PM50A60-60
|
|
|
|
|
60V
|
0.42A
|
60V
|
0.42A
|
50W
|
|
PM50B60-60
|
PM50C60-60
|
PM50D60-60
|
How to read our product code: E.g. PM50B15-15 PM50 = family code B =input range codeB 15-15 = two output voltages 12-16V
Input / Output
- Very wide input voltage ranges
- Input voltage ranges from
10 to 270Vd.c.
- Outputs from 12 till 132 Vd.c.
- Two isolated outputs 12 - 16V
or 60 Vd.c.
- Reverse input voltage protected
|
EMC, Safety & Environment base for CE mark
- EN60950 class I
- EN61000-6-3 Emission
- EN61000-6-2 Immunity
- EN/IEC61000-4-4, 4kV
- EN/IEC61000-4-5 level 2 & 3
- RoHS compliant (can optionally be lead soldered
|
|
Operation
- Operating temperature range-25 to +55°C
with derating +70°C
- Fully encapsulated IP20
- Convection cooled
|
Features
- Conformal coated
- Wall/chassis or DIN mounted
- One unit is flexible and the 2 outputs can be connected in different manners: , in parallel, series, as two separate or ±connected
|
Input voltage rating
Nominal input
|
Input voltage range
|
Code
|
|
12, 24 Vd.c.
|
10 - 30V
|
A
|
|
24, 28, 36, 48 Vd.c.
|
20 - 60V
|
B
|
|
72, 96, 110, 127 Vd.c.
|
50 - 150V
|
C
|
|
110, 127, 220, 250 Vd.c.
|
90 - 270V
|
D
|
Input voltage ranges that meets the railway standard EN50155/IEC60571, or other mobile applications. For nominal train input 36V use standard B-range and for 110V use standard C-input range.
The Polyamp PM50 series are extremly reliable, high MTBF and low noise DC/DC converters. Intended to be mounted on wall, DIN rail or chassies mount with 50W output power. Operating temperature range -25°c +55°C.
|
|
Last Updated on Monday, 04 January 2010 08:56 |