Skip to content
English (United Kingdom)Svenska (Sverige)

100W - 150W 2 - 3 outputs DC/DC converter

Print E-mail
PSC100 10TE, PSC150 12TE

PSC100 & PSC150 series

2-3 outputs DC/DC converters with 100W - 150W output power. They have high practical MTBF and are CE marked as fee standing unit. Can be installed in 19" subrack in Euro format 3HE 10TE, 12TE or also be mounted on wall, chassis and DIN rail. The master output ranges from 5V to 110V, the second slave output range from 5V to 30V and the third from -5V to -15V. The slave voltage nominal output current is 1.2 to 2 A with peak up to 3 A.
Input ranges from 10 V to 270 Vd.c. also with compatible AC/DC versions. Operating temperature range -25 to +55°C.

Get >> Datasheet Manual


Master output

Secondary outputs

Total power

5 V 10 - 20 A

±12V 1.2 - 2 A

100 - 150 W

5 V 10 - 20 A

12V 1.2 - 2 A

100 - 125 W

5 V 10 - 20 A

±15V 1.2 - 1.7 A

100 - 150 W

5 V 10 - 20 A 

15V 1.2 - 1.7 A

100 - 130 W

12 V 7.3 - 11 A

5V 2.5A2

100 - 150 W

12 V 7 - 11 A

12V 1.2 - 2 A

100 - 150 W

15 V 5 - 8 A

15V 1.2 - 1.7 A

100 - 150W

24 V 3 - 4.2 A

24V 1.2 - 2 A

100 - 150W

2 Common zero on output

Input /output
  • Wide input voltage ranges
  • Inputs from 10 - 300Vd.c.
  • Master output from 5 - 110 V
  • First slave output 5 - 30V
  • Second slave output 5- 15V 1.7 - 2 A peak 3 A
  • Reverse voltage protected input.

Operation

  • High efficiency
  • Operating temperature range -25 to +55°C, no derating.
    +70°C with derating
  • Fully encapsulated IP30.
  • Convection cooled.
  • Inhibit input
  • Pin compatible unit with AC-input,see PSC-AC data
Features
  • Conformally coated
  • Under voltage alarm with open collector.
  • Accessible from frontpanel:
    • Output voltage adjustment
    • Output voltage measurement
    • OutputOK status green LED
EMC, Safety & Environment base for CE mark
  • EN60950 class I
  • EN61000-6-3 Emission
  • EN61000-6-2 Immunity
  • EN/IEC61000-4-4, 4kV
  • EN/IEC61000-4-5 level 2 & 3
  • RoHS lead free soldered optionally

Input voltage ranges

Nominal input

Input voltage range

Code

12, 24 Vd.c.

10 - 30 V

A

24, 28, 36, 48 Vd.c.

20 - 60 V

B

48, 60, 72 Vd.c.

40 - 100 V

CT

72, 96, 110, 127 Vd.c.

50- 150 V

C

110, 127, 220, 250Vd.c.

90 - 270 V

D

Input voltage ranges that meets the railway standard EN50155/IEC60571, or other mobile applications. For nominal train input 36V use standard B-range and for 110V use standard C-input range.

Three outputs with output rating and type code. Input code A, B

Master Output

Slave Outputs

Total Power

Input voltage range

10 - 30 V

20 - 60 V

Case

 5 V 17 A  12 V 1.2 A 100 W  PSC100A5S12  PSC100B5S12 10TE
 5V 11 A  ±12 V 1.2 A 100 W  PSC100A5S12-12  PSC100B5S12-12 10TE
 5 V 20 A
 12 V 2 A
124 W
 PSC150A5S12
 PSC150B5S12 10TE
 5 V 20 A  ±12 V 2 A 150 W  PSC150A5S12-12  PSC150B5S12-12 12TE
 5 V 17 A  15 V 1.2 A 100 W  PSC100A5S15  PSC100B5S15 10TE
 5 V 10 A  ±15 V 1.2 A 100 W  PSC100A5S15-15  PSC100B5S15-15 10TE
 5 V 20 A  15 V 2 A 150 W  PSC150A5S15  PSC150B5S15 12TE
 5 V 20 A  ±15 V 1.7 A 150 W  PSC150A5S15-15  PSC150B5S15-15 12TE
 12 V 7.3 A  5 V 2.5 A2 100 W  PSC100A12S5  PSC100B12S5 10TE
 12 V 11 A
 5 V 2.5 A2 150 W  PSC150A12S5  PSC150B12S5 12TE
 12 V 7 A  12 V 1.2 A 100 W  PSC100A12S12  PSC100B12S12 10TE
 12 V 11 A  12 V 2 A 150 W  PSC150A12S12  PSC150B12S12 12TE
 15 V 5.5 A  15 V 1.2 A 100 W  PSC100A15S15  PSC100B15S15 10TE
 15 V 8 A  15 V 2 A 150 W  PSC150A15S15  PSC150B5S15 12TE
 24 3 A  24 V 1.2 A 100 W  PSC100A24S12-12  PSC100B24S12-12 10TE
 24 V 5 A  24 V 2 A 150 W  PSC150A24S12-12  PSC150B24S12-12 12TE
2 Common zero on the output.
Operating temperature range-25 till +55°C. +70°C with derating on PSC100 to 75 W & PSC150 to 110W. The slave outputs are only factory adjustable. Higher current on the slave outputs, up to 2.5A can be achieved by limiting the input voltage range.

Three outputs with output rating and type code. Input code CT, C, D

Master Output

Slave Outputs

Total Power

Input voltage range

40 - 100V

50 - 150V

90 - 270V

Case

 5 V 17 A  12 V 1.2 A 100 W  PSC100CT5S12  PSC100C5S12  PSC100D5S12 10TE
 5V 11 A  ±12 V 1.2 A 100 W  PSC100CT5S12-12  PSC100C5S12-12  PSC100D5S12-12 10TE
 5 V 20 A
 12 V 2 A
124 W
 PSC150CT5S12
 PSC150C5S12  PSC150D5S12 10TE
 5 V 20 A  ±12 V 2 A 150 W  PSC150CT5S12-12  PSC150C5S12-12  PSC150D5S12-12 12TE
 5 V 17 A  15 V 1.2 A 100 W  PSC100CT5S15  PSC100C5S15  PSC100D5S15 10TE
 5 V 10 A  ±15 V 1.2 A 100 W  PSC100CT5S15-15  PSC100C5S15-15  PSC100D5S15-15 10TE
 5 V 20 A  15 V 2 A 150 W  PSC150CT5S15  PSC150C5S15  PSC150D5S15 12TE
 5 V 20 A  ±15 V 1.7 A 150 W  PSC150CT5S15-15  PSC150C5S15-15  PSC150D5S15-15 12TE
 12 V 7.3 A  5 V 2.5 A2 100 W  PSC100CT12S5  PSC100C12S5  PSC100D12S5 10TE
 12 V 11 A  5 V 2.5 A2 150 W  PSC150CT12S5  PSC150C12S5  PSC150D12S5 12TE
 12 V 7 A  12 V 1.2 A 100 W  PSC100CT12S12  PSC100C12S12  PSC100D12S12 10TE
 12 V 11 A  12 V 2 A 150 W  PSC150CT12S12  PSC150C12S12  PSC150D12S12 12TE
 15 V 5.5 A  15 V 1.2 A 100 W  PSC100CT15S15  PSC100C15S15  PSC100D15S15 10TE
 15 V 8 A  15 V 2 A 150 W  PSC150CT15S15  PSC150C5S15  PSC150D5S15 12TE
 24 3 A  24 V 1.2 A 100 W  PSC100CT24S12-12  PSC100C24S12-12  PSC100D24S12-12 10TE
 24 V 5 A  24 V 2 A 150 W  PSC150CT24S12-12  PSC150C24S12-12  PSC150D24S12-12 12TE
2 Common zero on the output.
Operating temperature range-25 till +55°C. +70°C with derating on PSC100 to 75 W & PSC150to 110W. The slave outputs are only factory adjustable.
The slave outputs±12Vor ±15V has common zero. The slave outputs can be series connected to achieve 24V or 30V. Higher current on the slave outputs, up to 2.5A can be achieved by limiting the input voltage range.

How to read our product code:
E.g.PSC150B12S5
PSC150 = Family code
B = Input voltage range code
12 = masteroutput 12V
S5 = Stabilized slave output 5V

Last Updated on Wednesday, 10 August 2011 14:20
 
Banner
Banner

Newsletter




Besökare

Idag13
Igår145
Denna vecka333
Månad945
Alla37881

Newsflash

Our Åtvidaberg plant is expanded and refurbished we also a new entrace. The reason is increased demand of our DC/DC converters and that the production of the Systems division products has also been moved to the plant. In connection with the expansion we also changed the energy system and are using heat pumps charged by the Swedish Granite ground.