1000 - 2000W DC/DC converter convection and fan cooled |
|
|
PC2000-series 1000 to 2000W
The PC1000 series DC/DC converters are unique in the sense that it has convection cooling at 1000W and fan cooled for 1400 - 2000W output power, with two sligtly different mechanics. The fan cooled versions can still supply 1000W even in the case the fan do not operate. In reverse a PC1000 can operate in higher ambient temperature (+70°C) equiped with a thermostate reglulated fan.
| Input / Output
|
EMC, Safety & Environment base for CE mark
- EN60950 class I
- EN61000-6-3 Emission
- EN61000-6-2 Immunity
- EN/IEC61000-4-4, 4kV
- EN/IEC61000-4-5 level 2 & 3
- EN50121-3-2 & EN50121-3-2-4
IEC62236-3-2 & IEC62236-4
- RoHS compliant
|
| Operation
|
Features
- Active current sharing.
- External sens output
- Inrush current limit circuit.
- Overvoltage protection OVP.
- Alarm output with relay
- Inhibit input
|
Output data and type code
|
Output
|
Input voltage range
|
Voltage
|
Current
|
Power
|
20 - 32V
|
41 - 60V
|
93 - 150V
|
187 - 300V
|
Cooling
|
|
24V
|
42A
|
1000W
|
PC1000 24/24
|
PC1000 48/24
|
PC1000 110/24
|
PC1000 220/24
|
Convection
|
|
24V
|
58A
|
1400W
|
|
PC1400 48/24
|
PC1400 110/24
|
PC1400 220/24
|
Fan
|
|
28V
|
36A
|
1000W
|
PC1000 24/28
|
PC1000 48/28
|
PC1000 110/28
|
PC1000 220/28
|
Convection
|
|
28V
|
50A
|
1400W
|
|
PC1400 48/28
|
PC1400 110/28
|
PC1400 220/28
|
Fan
|
|
36V
|
28A
|
1000W
|
PC1000 24/36
|
PC1000 48/36
|
PC1000 110/36
|
PC1000 220/36
|
Convection
|
|
36V
|
42A
|
1400W
|
|
PC1400 48/36
|
PC1400 110/36
|
PC1400 220/36
|
Fan
|
|
48V
|
21A
|
1000W
|
PC1000 24/48
|
PC1000 48/48
|
PC1000 110/48
|
PC1000 220/48
|
Convection
|
|
48V
|
42A
|
2000W
|
|
PC2000 48/48
|
PC2000 110/48
|
PC2000 220/48
|
Fan
|
Other output voltage available on demand. To achieve 72V output 2x36V or 110V output 3x36V units can be series connected. Optional series diode on output is then needed.
How to read our product code: E.g. PC2000 110/48 PC2000 = family code 110 = input voltage range code 110V 48 = Output voltage 48 V
Input voltage data
Nominal Input
|
Input voltage range
|
Stop level
|
Code
|
|
24 Vd.c.
|
20 - 32V
|
<16.8Vd.c.
|
24
|
|
48 Vd.c.
|
43 - 60V
|
<33.6Vd.c.
|
48
|
|
110, 127 Vd.c.
|
90 - 150V
|
<77Vd.c.
|
110
|
|
220, 250 Vd.c.
|
180 - 300V
|
<154Vd.c.
|
220
|
Input voltage range: The range where we guaranty full operation, Vout +10%, Aout +5%. Stop level: The converter works down to the stop level, the output might drop to -10% of nominal output. Input voltage ranges that meets Railway standard EN50155/IEC60571 or other standards, can be provided on request.
|
|
Last Updated on Tuesday, 08 March 2011 19:21 |