Skip to content
English (United Kingdom)Svenska (Sverige)

550 - 600W DC/DC converter very wide input voltage range

Print E-mail
PU600

PU600-series 550 to 600W

Polyamp PU600 series DC/DC converters with output voltages  24V, 28V, 48V. Equipped with Inhibit input and an alarm circuit with potential free relay output and sens. An extra output wit series diode for parallel connection and a current sharing bus.
PU600 is unique with very wide input ranges from 18V to 300Vd.c.  Very high practical MTBF and CE marked as fee standing unit. Intended to be mounted on wall,  vehicle body and 19" rack.  Operating temperature range -25 to +55°C.

Get >> Datasheet Manual


Input / Output EMC, Safety & Environment base for CE mark
  • EN60950 class I
  • EN61000-6-3 Emission
  • EN61000-6-2 Immunity
  • EN/IEC61000-4-4, 4kV
  • EN/IEC61000-4-5 level 2 & 3
  • EN50121-3-2 & EN50121-3-2-4
    IEC62236-3-2 & IEC62236-4
  • RoHS lead free soldered optionally
Operation Features
  • Active current sharing in parallel connection
  • Extra output with series diode
  • External sens output
  • Inrush current limit circuit
  • Input and output over voltage protection
  • Over and under voltage alarm with relay
  • Inhibit input

Output voltage rating and type code

Output

Input voltage range

Voltage

Current

Power

20 - 60V

50 - 150V

90 - 270V

12V

40.0A

480W

PU600B12

PU600C12

PU600D12

13.8V

40.0A

552W

PU600B13.8

PU600C13.8

PU600D13.8

15V

40.0A

600W

PU600B15

PU600C15

PU600D15

24V

25.0A

600W

PU600B24

PU600C24

PU600D24

48V

12.5A

600W

PU600B48

PU600C48

PU600D48


How our product code works:

E.g. PU600 B12
PU600 = family code
B =input voltage range codeB
12 =output voltage 12 V

Input voltage rating

Nominal input

Input voltage range

Input Code

24, 48 Vd.c.

20 - 60 V

B

72, 96, 110, 127 Vd.c.

50 - 150 V

C

110, 127, 220, 250 Vd.c.

90 - 270 V

D

Input voltage ranges that meets Railway standard EN50155/IEC60571, can be provided on request. For nominal train input 36V use standard B-range and for 110V use standard C-input range.

Get >> Datasheet Manual



Last Updated on Wednesday, 17 November 2010 10:03
 
Banner