Remote sense

Print E-mail
Remote sense is used when the regulation at the load point is critical. The voltage regulation is moved to the load. Use a twisted pair cable. If the sense leads are very long they need to be shielded. The remote sense is standard on PSC/PSE series with 5V outputs and all DC/DC converters with 300W and higher power exept for PSC600 series where it is optional.
EN/IEC61000-4-6; 0.15 to 30MHz test can produce interferense only when remte sense is used. For shorter sense leads than 3 meters this test is not needed. Polyamp however test always according to this standard.
Last Updated on Monday, 04 January 2010 08:53
 
Banner
Banner

Newsletter




Besökare

Idag11
Igår145
Denna vecka331
Månad943
Alla37879

Newsflash

Our Åtvidaberg plant is expanded and refurbished we also a new entrace. The reason is increased demand of our DC/DC converters and that the production of the Systems division products has also been moved to the plant. In connection with the expansion we also changed the energy system and are using heat pumps charged by the Swedish Granite ground.