Menu

60 - 96 V inputs

60 Vd.c. is used mainly in telecom application on certain mar­kets. We can make special inputs for 48-60V input with 38-72V input. 72Vd.c. is used mainly in trains. Use our C input range or 72T.
96Vd.c. is not very common these days it has mainly been used in large fork-lifts. Use our C input range and require a series diode on the input.

 

Input Input range Family codes
60 Vd.c. B = 20 - 72Vd.c PSE100
60 - 96 V C = 50 - 150 Vd.c. PM50 PSE100 PSC150 PM150 PU300 PU600
60 Vd.c. 60 = 48 - 75 Vd.c. On demand
72 Vd.c. 72 = 60 - 100Vd.c. On demand
72 Vd.c. 72T = 43.2 -100.8Vd.c For train EN 50155/IEC 60571 and forklifts, on demand


Polyamp guarantee full performance within the specified input range, which means 105% load capacity, 110% output voltage level at max rated operational temperature.

Login